Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Organ Transplantation ; (6): 610-2020.
Article in Chinese | WPRIM | ID: wpr-825580

ABSTRACT

Objective To evaluate the application value of quantitative parameters of contrast-enhanced ultrasound (CEUS) in evaluating the donor liver from donation after brain death (DBD). Methods Clinical data of 25 DBD donor livers and 10 healthy adult livers were retrospectively analyzed. CEUS examinations of DBD donor livers and healthy livers were collected. Quantitative parameters included the area under curve (AUC), maximum intensity (Imax), time to peak (TTP) and mean transit time (mTT), etc. Results Among 25 cases of DBD donor livers, 23 cases showed normal enhancement pattern, and the other 2 cases presented with abnormal enhancement pattern. Compared with the control group, the AUC, Imax and mTT values of DBD donor livers were significantly decreased (all P < 0.05). Conclusions CEUS quantitative parameters can be effective means to evaluate the micro-perfusion of DBD donor livers.

2.
Chinese Journal of Practical Nursing ; (36): 41-43, 2013.
Article in Chinese | WPRIM | ID: wpr-437421

ABSTRACT

Objective To make a concrete analysis of micro-perfusion pump and compatible syringes used in neonatal intensive care unit (NICU) for low birth weight infants,and to find solutions to the defects in application.Methods 20 ml sterile syringes were set different infusion rates (1ml/h,5ml/h,6ml/h,10ml/h),different infusion time (5min,30min,lh).Then,the card slot on the micro-perfusion pump where the end of 20ml sterile syringe was placed was regulated.The regulated syringes were also set different infusion rates (5ml/h,6ml/h,l0ml/h) and time as before.The error accuracy was calculated.Results The results showed that at the end stage of 20ml sterile syringes pumping,there was always 0.5~1.5 ml residual liquid which could not be pumped out,but perfusion pump displayed injection was completed.Before regulation,the error accuracy between different infusion rates of 20ml sterile syringes was 6.00%,3.80%,2.33%,1.30% respectively.However,after improvement,the regulated syringes could completely pump all liquid out,and the error accuracy between different infusion rates and different infusion time was also superior to pre-improvement.Conclusions Improved micro-infusion pump and sterile solution prefilled syringe have no drug residual,and display high accuracy and small error accuracy.

SELECTION OF CITATIONS
SEARCH DETAIL